TCPRK-BBU
SERIES
|
| |
| |
Other
Products |
| |
Related Products
|
|
 |
|
RUGGED DC UPS
- RACK MOUNT DC UPS
- RUGGED MILITARY DC UPS
- rUGGED COTS DC UPS
- CUSTOM DC UPS POWER SYSTEM |
Shown with the cover removed |
Technology Dynamics offers a full array of Rugged DC UPS Systems to suit any commercial, industrial, or military application, including those that require DC UPS's which can withstand Military Environmental and Electrical Standards such as MIL-STD-810, MIL-STD-167, MIL-STD-1399, MIL-STD-461, and more. These Rugged UPS Systems are available in rack mount, panel mount and custom configurations to suit applications with tight space constraints.
Any Standard input voltage (single or three phase) can be accommodated, in 50, 60, or 400 Hz frequencies, changing a given input voltage and frequency to a DC output voltage with battery configurations designed to meet your load and reliable performance, as well as the resulting MTTR, high MTBF, and Cost-To-Own figures. |
|
|
|
STANDARD SINGLE OUTPUT DC POWER SUPPLY |
As standard we have available our TCPRK series with very short cycle availability for Battery Backup Applications.
|
The TCPRK
Series satisfies an emerging market
where "critical" continuous
power is required. Designed as
a complete system with power supply,
charger and board batteries, loaded
with standard features the TCPRK-BBU
Series is ideal for medical, industrial
and communication applications.
|
|
|
| TCPRK-BBU-5-60 |
3.3/5V |
60A |
TCPRK-BBU-5-80 |
80A |
Consult
Factory |
| TCPRK-BBU-12-34 |
12V |
34A |
TCPRK-BBU-12-50 |
50A |
| TCPRK-BBU-15-27 |
15V |
27A |
TCPRK-BBU-15-40 |
40A |
| TCPRK-BBU-24-17 |
24V |
17A |
TCPRK-BBU-24-25 |
25A |
TCPRK-BBU-24-41 |
41A |
| TCPRK-BBU-36-11 |
36V |
11A |
TCPRK-BBU-36-16 |
16A |
Consult
Factory |
| TCPRK-BBU-48-8 |
48V |
8A |
TCPRK-BBU-48-12 |
12A |
TCPRK-BBU-48-20 |
20A |
NOTE: OTHER RACK
SIZES AVAILABLE DEPENDING ON POWER LEVES
AND BATTERY SIZE

|
LOW VOLTAGE BATTERY
DISCONNECT
The LVBD module adds a new dimension
to battery backup power supplies. The
power supply simultaneously charges
the battery and powers the load. If
the AC power fails the battery continues
to support the load. However, when the
battery voltage drops below a predetermined
level, the LVBD module disconnects the
battery from the load, thereby protecting
the battery from the damaging effects
of complete discharge.
|
| AUTO
LINE SELECT |
-ALS |
| POWER FACTOR CORRECTION |
-PFC |
| REDUNDANT OPERATION |
-ORD |
| FORCED CURRENT SHARING |
-FCS |
| RUGGED/MILITARIZED |
-MIL |
| HOT PLUGABBLE |
-HSP |
| MS CONNECTOR
|
-MSC |
| WIDE TEMP OPERATION |
-WTD |
|

- Compact,
light weight
- Rugged
constreuction
- OV/OL/OT
Protected
- Built-In
On Board batteries
- Input and
battery circuit breakers
- Voltage
& Current Meters
- Visual and
electronic signals
- Low
voltage battery disconnect

- Redundant
Operation (N+1)
- Forced
Current Sharing
- Low
Voltage Battery Disconnect
(LVBD) for battery back-up operation.
- Wide
temperature range
- Auto
line selection
-
Power Factor Correction
- Ruggedized
|
|

ELECTRICAL:
AC Input Voltage : 90-132/180-264
VAC Standard, Auto-Line Selection optional.
AC Input Frequency: 47-63Hz Standard,
47-400Hz optional
Regulation: Line ± .3%
Load + 2%
Ripple: 1% peak to peak, not to
exceed 100mVpp
Efficiency: 85% typical
Output voltage adj: +10%
on main output
Overvoltage Protection: Set at
120% of main output, automatic recovery
Overload Protection:
Current limiting, automatic recovery
Operating Temperature:
0°C to + 50°C standard
-40°C to 75°C optional
Storage Temperature: -40°C
to 85°C
Cooling: Internal ball bearing
DC fan
Safety: meets UL 1950,
CSA 1402 A
EMI: meets FCC Class
A
Humidity: 90% non condensing
Size: 3.5" (H) x
19" (W) x18" (D)
Weight: Approx: 25lbs (depending
on battery type & size)
|
|

|
|