hOT SWAP DC UPS
BATTERY BACKUP POWER SUPPLY
COMPLETE REDUNDANCY wITH BATTERY BACKUP
- SEVERE ENVIRONMENT DC UPS
- SINGLE OUTPUT DC UPS
- CUSTOM DC UPS POWER SYSTEM |
Power Supply and Rack Battery
|
The TCPHS-BBU DC UPS Series satisfies an emerging market where critical continuous power is required. Designed as a complete system with power supply, charger and on board batteries, loaded with standard features the TCPHS-BBU Series is ideal for medical, critical industrial, homeland security and communications applications where no downtime can be tolerated.
|
|
|
|

Assuming 3 modules per rack shelf
TCPHS-BBU-12-102 |
12V |
102A |
TCPHS-BBU-12-150 |
150A |
Consult Factory |
TCPHS-BBU-24-51 |
24V |
51A |
TCPHS-BBU-24-75 |
75A |
TCPHS-BBU-24-123 |
123A |
TCPHS-BBU-48-24 |
48V |
24A |
TCPHS-BBU-48-36 |
36A |
TCPHS-BBU-48-60 |
60A |
Note: Separate power supply racks and draws are available for increased power levels and back up times. Other voltages and currents are available, contact the factory for details.

| POWER |
BACKUP TIME |
MODEL |
| 1200W |
| 12V) = 20 min |
| (24V) = 20 min |
| (48V) = 20 min |
|
TCP-BTRY-1200W |
| 1800W |
| (12V) = 13 min |
| (24V) = 13 min |
| (48V) = 13 min |
|
TCP-BTRY-1800W |
| 3000W |
| (12V) = 5 min |
| (24V) = 5 min |
| (48V) = 5 min |
|
TCP-BTRY-3000W |

|
LOW VOLTAGE BATTERY
DISCONNECT
The LVBD module adds a new dimension
to battery backup power supplies. The
power supply simultaneously charges
the battery and powers the load. If
the AC power fails the battery continues
to support the load. However, when the
battery voltage drops below a predetermined
level, the LVBD module disconnects the
battery from the load, thereby protecting
the battery from the damaging effects
of complete discharge.
|
| AUTO
LINE SELECT |
-ALS |
| POWER FACTOR CORRECTION |
-PFC |
| REDUNDANT OPERATION |
-ORD |
| FORCED CURRENT SHARING |
-FCS |
| RUGGED/MILITARIZED |
-MIL |
| HOT PLUGABBLE |
-HSP |
| MS CONNECTOR |
-MSC |
| WIDE TEMP OPERATION |
-WTD |
|

- Hot swap
- Compact, light weight
- Rugged
construction
- OV/OL/OT
Protected
- Built-In
On Board batteries
- Input and
battery circuit breakers
- Voltage
& Current Meters
- Visual and
electronic signals
- Low
voltage battery disconnect

- Wide
temperature range
- Auto
line selection
-
Power Factor Correction
- Ruggedized
- 3 Phase Input
|
|

ELECTRICAL:
AC Input Voltage : 90-132/180-264
VAC Standard, 90-26V Universal Input Optional.
AC Input Frequency: 47-63Hz Standard,
47-400Hz optional
Regulation: Line ± .3%
Load + 2%
Ripple: 1% peak to peak, not to
exceed 100mVpp
Efficiency: 85% typical
Output voltage adj: +10%
on main output
Overvoltage Protection: Set at
120% of main output, automatic recovery
Overload Protection:
Current limiting, automatic recovery
Operating Temperature:
0°C to + 50°C standard
-40°C to 60°C optional
Storage Temperature: -40°C
to 85°C
Cooling: Internal ball bearing
DC fan
Safety: meets UL 1950,
CSA 1402 A
EMI: meets FCC Class
A
Humidity: 90% non condensing
Size:
3.5" (H) x 19" (W) x 18" (D) power supply rack
3.5" (H) x
19" (W) x18" (D) battery rack
Weight:
Approx: 25lbs (power supply rack)
Approx: XXlbs battery rack, depending