|

- Power Factor
correction
- Hot Swap
Elcon connector
- Active current
sharing on the main 3 outputs: 5V and
3.3V
- Remote
inhibit
- Remote sensing
on +5V and 3.3V outputs
- O-ring diodes
all outputs
- Power Good
signal and indicator
- High peak
current all outputs
- Temperature
Good indicator
- Fan failure
indicator
- Designed
for UL 1950 and CE requirement
- Meets
NEBS

- Ruggedized
for severe environmen
- Back Plane
for 2 modules.
- Rack enclosure
for redundant operation
|
|

ELECTRICAL:
Input: 100-264 VAC 50/60
Hz
Regulation: Line ±
2% Load ± 2%
Ripple: 50mV peak
to peak
Efficiency: 80% typical
Hold up Time: 20 msec
Inrush Current: 40A max
Protections: OVP, OCP,
OTP, Fan Failure
Logic signals and controls:
Inhibit, Power Good, Fan Good, Current
Share Bus,
Temperature Good, Current indicator +5,
+3.3V & +12V outputs. 0-5V for 0-Full
load
Operating
Temperature:
0°C to +50°C
Standard
-40°C to +65°C Optional
Storage Temp.:
-40°C to +85°C
Cooling: Internal fan
|