topnav.gif
 
   
   
 
 

 


TCP- HS SERIES


Other Products

 

 

HOT SWAP

400 - 3000 WATTS
2U hIGH, (N+1) REDUNDANT
POWER SYSTEM



The low-cost TCP-HS Series of Hot Swap Rack Systems offers low height, (N+1) redundant configurations of 2 or 3 modules per enclosure. This series is especially suitable for critical telecommunication / wireless systems


MODEL
OUTPUT
1200W OR 400W PER MODULE
NOMINAL VDC @ MAXIMUM ADC
TCP-HS-5-180
3.3/5V@180A
TCP-HS-12-102
12V@102A
TCP-HS-15-81
15V@81A
TCP-HS-24-51
24V@51A
TCP-HS-36-33
36V@33A
TCP-HS-48-24
48V@24A
1800W OR 600W PER MODULE
NOMINAL VDC @ MAXIMUM ADC
TCP-HS-5-240
5V@240A
TCP-HS-12-150
12V@150A
TCP-HS-15-120
15V@120A
TCP-HS-24-75
24V@75A
TCP-HS-36-48
36V@48A
TCP-HS-48-36
48VDC@36A
3000W OR 1000W PER MODULE**
NOMINAL VDC @ MAXIMUM ADC
TCP-HS-24-123
24V@123A
TCP-HS-48-60
48V@60A


  • 2U (3.5") High, 19" Wide Rack-Mount Enclosure
  • MTBF >150,000 Hours
  • LED Indicators (each module):
    Output Power (good)
    Input Power (good)
  • All outputs tightly regulated
  • All outputs equipped with Isolation diodes for redundancy
  • Forced Current Sharing
  • OV/OL/OT Protection Main Output
  • Floating connectors for hot-swap insertion
  • Remote Sensing post isolation diodes

  • Power Factor Correction
  • Militarized / Ruggedized to meet MIL-STD-810
  • LVBD*: Low Voltage Battery Disconnect for battery back-up operation (see below for details)
  • Circular connectors type MS-3102
  • Central Office White
  • 23" Wide Rack Panel

    *Low Battery Voltage Disconnect (LVBD): The LVBD Module adds a new dimension to battery backup power supplies. The power supply simultaneously charges the battery and powers the load. If input power fails, the battery continues to support the load. However, when the battery voltage drops below a predetermined level, the LVBD module disconnects the battery from the load, thereby protecting the battery from the damaging effects of complete discharge.
 

ELECTRICAL:

AC input voltage: Auto-Select (85-132) - (175-265) VAC
Input Frequency: 47-63 Hz
Efficiency: 80% typical for Single-Output units, 70% typical for 4 multiple outputs units
Line Regulation: +.3%
Load Regulation: +2%
Ripple & Noise: 1% peak to peak, not to exceed 100mV
Protections: OV, OL, & OT
Hold-up time: 20ms minimum
In-Rush Current: 60A Max 1/2 cycle



Operating temperature: -0°C to +50°C standard, -40°C to +60°C optional
Storage temperature: -40°C to +85°C
Cooling: Internal ball bearing DC fan
Size: 17.9" (L) x 19" (W) x 3.5" (H)
Weight: 25 Lbs. (11.3 kg) for 3 Module System

 
 

 