topnav.gif
 
   
 
 

 


TDL- HS SERIES


Other Products

 

 

hOT SWAP

1000 - 3000W
3U hIGH (N+1) REDUNDANT
SINGLE / MULTIPLE OUTPUT
RACK MOUNT POWER SYSTEM



The low-cost TDL-HS Series of Hot Swap Rack Systems offers low height, (N+1) redundant configurations of 2 or 3 modules per enclosure. This series is especially suitable for critical telecommunication systems, computer systems, and COTS military applications.


SINGLE / MAIN OUTPUT (3 MODULES)

OUTPUT
MAX LOAD
MODEL NO
5/3.3
125
TDL-HS-5-125
12
100
TDL-HS-12-100
24
85
TDL-HS-24-85
28
75
TDL-HS-28-75
48
22
TDL-HS-48-22


MULTIPLE OUTPUT

OUTPUT #2 (-V2)
VDC @ MAX AMP
CODE
-5V@6A
A1
-12V@6A
A2
-15V@6A
A3
-24V@3A
A4

OUTPUT #3 (+V3)
VDC @ MAX AMP
CODE
-5V@10A
B1
+12V@10A
B2
+15V@10A
B3
+24V@3A
B4

OUTPUT #4 (V4)
VDC @ MAX AMP
CODE
5V@6A
C1
12V@6A
C2
15V@6A
C3
24V@6A
C4

OUTPUT #5 (V5)
VDC @ MAX AMP
CODE
5V@20A
D1
12V@16A
D2
15V@14A
D3
24V@9A
D4

OUTPUT #6 (-V6)
VDC @ MAX AMP
CODE
5V@20A
E1
12V@16A
E2
15V@14A
E3
-24V@9A
E4

** Other models available. Please consult factory for details.

  • 3U (5.25") High, 19" Wide Rack-Mount Enclosure
  • 1 to 6 Outputs
  • MTBF >150,000 Hours
  • LED Indicators (each module): Output Power (good) Input Power (good)
  • All outputs tightly regulated
  • All outputs equipped with Isolation diodes for redundancy
  • Forced Current Sharing
  • OV Protection Main Output
  • Floating connectors for hot-swap insertion
  • Remote Sensing post isolation diodes

  • ORD: Wide Temperature Option
  • MIL: Militarized / Ruggedized to meet MIL-STD-810
  • LVBD*: Low Voltage Battery Disconnect for battery back-up operation (see below for details) - Main Output only
  • UPS: Battery Backup (All Outputs)

    *Low Battery Voltage Disconnect (LVBD): The LVBD Module adds a new dimension to battery backup power supplies. The power supply simultaneously charges the battery and powers the load. If input power fails, the battery continues to support the load. However, when the battery voltage drops below a predetermined level, the LVBD module disconnects the battery from the load, thereby protecting the battery from the damaging effects of complete discharge.
 

ELECTRICAL:

AC input voltage: 110/230 VAC Auto Select
Input Frequency: 47-63 Hz
Efficiency: 80% typical for Single-Output units, 70% typical for 4 multiple outputs units
Line Regulation: +.3%
Load Regulation: +2%
Ripple & Noise: 1% peak to peak, not to exceed 100mV
Protections: OV, OL, & OT
Hold-up time: 20ms minimum
In-Rush Current: 60A Max 1/2 cycle




Operating temperature: -0°C to +50°C standard, -30°C to +60°C optional
Storage temperature: -30°C to +85°C
Cooling: Internal ball bearing DC fan
Size: 5.25" (H) x 19" (W) x 17.9 (L)
Weight: 25 Lbs. (11.3 kg) for 3 Module System

 
 

 

Technology Dynamics