NTDM
SERIES
|
|
Other Products
|
|
|
Pdf
Downloads
|
|
 |
|
|
AC -
DC POWER SUPPLY |
 |
SINGLE OUTPUT
BULK
POWER / RUGGED DESIGN
1000-3000
Watts
|

The NTDM DC Output Power Supply Series has been in wide
use in such applications as RF &
Microwave transceivers, Telecom
systems, battery charging or replacement
and burn-in systems. Over 3000 units
have been deployed in military applications
aboard surface vehicles and ships.
These units can be ruggedized and utilized in COTS, Modified and Custom DC Output Applications.
|
|
 |
|
|
5.0 |
200 |
NTDM-5-200 |
300 |
NTDM-5-300 |
CONSULT FACTORY |
CONSULT FACTORY |
|
12 |
83 |
NTDM-12-83 |
125 |
NTDM-12-125 |
|
15.0 |
63 |
NTDM-15-67 |
100 |
NTDM-15-100 |
|
24.0 |
42 |
NTDM-24-42 |
62 |
NTDM-24-62 |
84 |
NTDM-24-84 |
125 |
NTDM-24-125 |
|
28.0 |
36 |
NTDM-28-36 |
54 |
NTDM-28-54 |
72 |
NTDM-28-72 |
107 |
NTDM-28-107 |
|
48.0 |
21 |
NTDM-48-21 |
31 |
NTDM-48-31 |
42 |
NTDM-48-42 |
62 |
NTDM-48-62 |
|
110.0 |
9 |
NTDM-110-9 |
14 |
NTDM-110-14 |
18 |
NTDM110-18 |
27 |
NTDM-110-27 |
*2kw and 3kw
units are available only with 220VAC single
phase or 115/220VAC 3 Phase Input.
Additional Ouput Voltages Are Available. Contact
The Factory for more info.
|
LOW VOLTAGE BATTERY
DISCONNECT
The LVBD module adds a new dimension to
battery backup power supplies. The power
supply simultaneously charges the battery
and powers the load. If the AC power fails
the battery continues to support the load.
However, when the battery voltage drops
below a predetermined level, the LVBD
module disconnects the battery from the
load, thereby protecting the battery from
the damaging effects of complete discharge.
|
| AUTO LINE
SELECT |
-ALS |
| POWER FACTOR CORRECTION |
-PFC |
| REDUNDANT OPERATION |
-ORD |
| 3 PHASE INPUT |
-3P |
| RUGGED/MILITARIZED |
-MIL |
| HOT PLUGABBLE |
-HSP |
| BATTERY BACK-UP |
-LVBD |
|

- Battery
back-up
- Auto-selectable
inputs
- Redundancy
(N+1) configuration
- Power factor
correction
- 3 phase
input
- Hot pluggable
|
|

ELECTRICAL:
Input: 90-132/180-264 VAC
(user selected), 47-63 Hz
Regulation: Line .2%
Load .5% from min to max load
Ripple: 1% of output or
200 mVpp whichever is smaller, measured
at terminals,
DC to 20 Mhz bandwidth
Efficiency: 75%
to 85% typ full load Hold
up time: 20ms min.
InRush Current: 40 peak
maximum
Protections: OV, OL &
OT
Operating Temperature: 0°C
to +50°C ambient for full output power
Storage Temperature:
-30°C to +85°C
Cooling: DC-Operated ball
bearing fan Size: 5"(H)
x 8"(W) x 12.5"(L)
|
|

|
|