AC -
DC POWER SUPPLIES
|
 |
SINGLE
OUTPUT, pOWER FACTOR CORRECTED
400 - 1000 WATTS
|
APPLICATIONS
INDUSTRIAL, MILITARY, "COTS", CUSTOM, COMMERCIAL, COMMUNICATIONS, & MEDICAL
The PTCP series of Power Factor Corrected AC-DC power supplies provides highly regulated output power from 400-1000 watts. Rugged construction and superior quality make this power supply ideal for harsh environment applications from -40 to +55 °C. Available in standard, modified or fully custom configurations, for industrial, commercial, COTS, ruggedized, and Military / Mil-Spec applications.
Features:
|
|
|
|
 |
|
• -40 to 55°C Wide Temp Operation, Rugged Construction
|
|
• Parallel / Redundant Operation (N+1) Hot Swap, Rack Mount, Panel Mount |
| • Designed to Withstand High Shock & Vibration (MIL -STD-810) |
• 100% Single Wire Current Sharing, ORing Diode Protection
|
• 115/230 VAC Single Phase / 3 Phase Input,
47-400Hz |
• Programmable, Superior Quality, Low Cost, In Stock |
| • Power Factor Corrected, Suitabe for Battery Back-up &
DC-UPS modified and custom applications. |
• Standard, Modified, "COTS" Semi-Custom & Custom versions avalable |
SINGLE
OUTPUT POWER SUPPLIES
| PTCP-5-60 |
3.3/5Volts |
60Amps |
PTCP-5-80 |
80Amps |
Consult Factory |
| PTCP-12-34 |
12Volts |
34Amps |
PTCP-12-50 |
50Amps |
| PTCP-15-27 |
15Volts |
27Amps |
PTCP-15-40 |
40Amps |
| PTCP-24-17 |
24Volts |
17Amps |
PTCP-24-25 |
25Amps |
PTCP-24-41 |
41Amps |
| PTCP-36-11 |
36Volts |
11Amps |
PTCP-36-16 |
16Amps |
Consult
Factory |
| PTCP-48-8 |
48Volts |
8Amps |
PTCP-48-12 |
12Amps |
PTCP-48-20 |
20Amps |
*
CONTACT THE FACTORY FOR MULTIPLE OUTPUT VERSION
|
LOW VOLTAGE BATTERY
DISCONNECT
The LVBD module adds a new dimension
to battery backup power supplies. The
power supply simultaneously charges
the battery and powers the load. If
the AC power fails the battery continues
to support the load. However, when the
battery voltage drops below a predetermined
level, the LVBD module disconnects the
battery from the load, thereby protecting
the battery from the damaging effects
of complete discharge.
|
| WIDE TEMPERATURE OPERATION |
-WTO |
| REDUNDANT OPERATION |
-ORD |
| FORCED CURRENT SHARING |
-FCS |
| RUGGED/MILITARIZED |
-MIL |
| HOT PLUGABBLE |
-HSP |
| BATTERY BACK-UP |
-LVBD |
|

- Low cost,
high reliability
- Compact
size, light weight
- Low noise
and ripple
- Terminal
block input
- Rugged designed
for shock and vibration
- Rugged designed
for shock and vibration
- Built in
fan
- Over voltage,
overload & over temp
- Full load
burn-in test
- Ideal for COTS Applications

- Redundant
Operation (N+1)
- Forced
Current Sharing
- Low
Voltage Battery Disconnect
(LVBD) for battery back-up operation.
- Wide
temperature range
- 400 Hz Input
- Ruggedized for shock and vibration
- Rack mount / Panel Mount
- Parallel operation
|
|

ELECTRICAL:
AC InputVoltage : 90-264
VAC Universal Input.
AC Input Frequency: 47-63Hz Standard,
47-400Hz optional
Regulation: Line ± .3%
Load + 2%
Ripple: 1% peak to peak, not to
exceed 100mVpp
Efficiency: 85% typical
Output voltage adj: +10%
on main output
Overvoltage Protection: Set at
120% of main output, automatic recovery
Overload Protection:
Current limiting, automatic recovery
Operating Temperature:
0°C to + 55 °C standard
-40°C to 55 °C optional
Storage Temperature: -40°C
to 85°C
Cooling: Internal ball bearing
DC fan
Safety: meets UL 1950,
CSA 1402 A
EMI: meets FCC Class
A
Humidity: 90% non condensing
Size: 11.5" (L)
x 4.75" (W) x 2.625" (H)
Weight: 6.6 lb (3kg) max.
|
|

|
|